DIV-22 Sample Plumbing Fixture Trim Spec

P-Traps Lavatory and sink p-traps shall be (1-1/4, 1-1/4 x 1-1/2 IN, 1-1/2, 1-1/2 x 2 IN, 2 IN) chrome plated cast brass, (adjustable, ground joint swivel, NV, sweat styles) (with, without) cleanout, with (17 GA seamless brass adjustable wall bend, cast brass nipple, 17 GA seamless sweat tube), cast brass slip nuts, no reducing washers. P-Trap shall be provided with (shallow, deep, bell) (steel, brass, forged brass with setscrew) flange. P-Trap to have 2 IN water seal and rough-in complete, adapter extensions are not allowed. P-Trap shall be certified by CSA or another recognized testing authority and marked with manufacturer's name. Part# shall be McGuire _____________
Supply Kits Lavatory and closet supply kits shall include chrome plated all brass stops with brass stems, no plastic stems. Kits shall include (12, 15, 20 IN) chrome plated copper riser(s) and, (shallow, deep, bell) (steel, brass, forged brass with setscrew) flange(s). Inlet shall be (3/8, 1/2 IN) (IPS, sweat, sweat with 5 IN extension, compression). Outlet shall be (3/8, 1/2 IN) (IPS, compression). The supply kit shall be certified by a recognized testing authority, marked with manufacturer's name, and comply with the SDWA 
(Safe Drinking Water Act) No lead restrictions of ANSI NSF 61, Sec. 9. Part# shall be McGuire __________
Integral Check Valve (ICV Defender) Supply stop valve shall be chrome plated all brass full turn supply stop valve with spring actuated integral check and brass stem. The inlet shall be (3/8, 1/2) inch (IPS, sweat, sweat with 5" compression, compression). Outlet shall be (3/8", ½" ) inch (IPS, compression). supply stop valve. Integral check supply stop valve shall be certified and recognized by the testing authority and marked with the manufacturer's logo and testing marks and comply with SDWA (Safe Drinking Water Act) No lead restrictions of ANSI NSF 61, Sec. 9. Part# shall be McGuire ____________
Supply Kit with Integral Check Valve Lavatory and closet supply kits shall include chrome plated all brass full turn supply stop valve with spring actuated integral check and brass stem. Inlet shall be (3/8, 1/2) inch (IPS, sweat, sweat with 5" compression, compression). Outlet shall be (3/8", ½") inch (IPS, compression). Supply kit(s) shall have (12", 15", 20") chrome plated copper riser(s) and (shallow, deep, bell) (steel, brass, forged brass with setscrew) flange(s). Supply kit shall be certified by a recognized testing authority, marked with the manufacturer's logo and testing marks, and comply with SDWA (Safe Drinking Water Act) No lead restrictions of ANSI NSF 61, Sec.9. Part# shall be McGuire _________
Grid Drains Grid Drains Lavatory grid drains (offset grid drains) shall be (1-1/4, 1-1/2 IN) chrome plated cast brass strainer (with, without overflow) and brass lock nut. The drain tailpiece shall be a 17 GA seamless brass tube and a minimum of 6 IN long. Grid drain shall be certified by CSA or other recognized testing authority and be marked with the manufacturer's name. 
Part# shall be McGuire ______
ADA Seamless Insulator Covers All-Inclusive with Chrome Brass P-Trap ADA Seamless Insulator Covers and PreWrapped P-Traps  All exposed lavatory and sink trim on wheelchair-accessible fixtures shall be covered with the seamless antimicrobial vinyl insulating outer shell. Material shall be flame retardant, fungal, and bacterial resistant. Insulating kits shall include a cover for the drain tailpiece, all p-trap brass components, and covers for hot and cold supplies. Part# shall be McGuire ____________
Antimicrobial Product Protection (SANIGUARD) SANIGUARD® Antimicrobial Product Protection  SANIGUARD antimicrobial product protection inhibits the growth of common non-public health bacteria, mods, and fungi that cause odors, staining, and product deterioration on treated surfaces. This product is not a disinfectant and does not protect the user or others against food-borne illnesses or disease-causing bacteria, viruses, or germs. Always use proper hygiene and cleaning procedures. Part# shall be McGuire __________